This article is from Journal of Emergencies, Trauma and Shock , volume 4 . Abstract Background:: Uncontrolled hemorrhage is one of the leading causes of death in both combat and civilian trauma. This study was designed to compare the arterial blood pressures at which rebleeding occurred when a hemostatic agent, ExcelArrest™, was used compared with a standard pressure dressing. Materials and Methods:: This study was a prospective, experimental, and mixed research design. Swine were assigned to one of two groups: ExcelArrest™ (n=5) or a control consisting of standard pressure dressings (n=5). Investigators generated a complex groin injury. The femoral artery and vein were transected and allowed to bleed for 60 s in each pig. After 60 s, ExcelArrest™ was poured into the wound. The control group underwent the same procedures, but without treatment with the hemostatic agent. After 5 min of direct pressure, a standard pressure dressing was applied. After 30 min, dressings were removed and the systolic blood pressure (SBP) was increased incrementally using intravenous phenylephrine until rebleeding occurred. Statistical Analysis:: A multivariate ANOVA and a least significant difference we
Sign in with your free account to read, download EPUBs or listen.
Ebook · The effects of blood pressure on rebleeding when using ExcelArrest(TM) in a porcine model of lethal femoral injury. · Hirst, HaYong, Brinkman, John, Beasley, Amy, Crocker, Richard, O'Sullivan, Joseph · Internet Archive