English
This article is from Surgical Neurology International , volume 3 . Abstract Background:: The craniotomy performed with minimal hair removal and closure with intradermal suture alone is an option in neurosurgical procedures, which can help faster psychological recovery of the patient, as it allows a better cosmetic result. This study is aimed at evaluating if such method is safe and effective, compared with continuous skin sutures with 2-0 nylon. Methods:: We analyzed the sutures in 117 patients undergoing craniotomies for cerebral aneurysm clipping. In the case group (n = 49), closure of the scalp was performed only with intradermal absorbable sutures using wire Monocryl® 2-0. In the control group (n = 68), closure was performed with continuous suture using 2-0 nylon. Results:: The case group was composed of 49 patients in whom just intradermal suture was performed. One (2.2%) patient developed wound infection and was given proper medical treatment. No cases of dehiscence or cerebrospinal fluid leaks were observed. The control group was composed of 68 patients in whom the skin was closed with 2-0 nylon continuous suture. Three (5.3%) patients developed wound infection and were give
Sign in with your free account to read, download EPUBs or listen.
Ebook · Skin closure in vascular neurosurgery: A prospective study on absorbable intradermal suture versus nonabsorbable suture. · Pereira, Julio Leonardo Barbosa, Vieira, Gerival, de Albuquerque, Lucas Alverne Freitas, Mendes, George de Albuquerque Cavalcanti, Salles, Ludmila Rezende, de Souza, Andre Felipe Ferreira, Dellaretti, Marcos, de Sousa, Atos Alves · Internet Archive