English
This article is from Indian Journal of Anaesthesia , volume 56 . Abstract Background:: Central venous catheters (CVC) are associated with mechanical, infectious and thrombotic complications. Aims:: To study (a) the incidence of mechanical and infectious complications of CVC insertions and to compare, (b) the rates of these complications between the internal jugular venous (IJV) and the subclavian venous (SCV) accesses. Settings and Design:: An adult intensive care unit of a tertiary care hospital. Prospective, observational study. Methods:: All landmark-based CVC insertions performed between 1st October 2008 and 30th September 2009 were prospectively studied for mechanical and infectious complications. Statistical Analysis:: SPSS software for Windows, Version SPSS 16.0, and Epi Info (3.5.1) software. Results:: Four hundred and eighty central venous catheterizations were studied (IJV route, 241 and SCV route, 239). Mechanical complications occurred in 86 patients (17.9%, bleeding complications-48, catheter-related complications-27 and pneumothorax-11). The IJV route was associated with a significantly higher incidence of bleeding complications (P=0.009). Forty-seven patients had inf
Sign in with your free account to read, download EPUBs or listen.
Ebook · Mechanical and infectious complications of central venous catheterizations in a tertiary-level intensive care unit in northern India. · Kaur, Randeep, Mathai, Ashu Sara, Abraham, John · Internet Archive