This article is from Indian Journal of Orthopaedics , volume 47 . Abstract Background:: Anterior fixation using two 3.5 mm screws is typically recommended for type II odontoid fractures. However, it is unsuitable in patients with an odontoid diameter of <9.0 mm. There is no data regarding the morphology of odontoid process in the Indian population. The aim of our study was to: a) Measure the external diameters of odontoid process in the Indian population using CT scan and thus determine the feasibility of two 3.5 mm screw fixation in them. b) Determine if any correlation exists between body height (Ht) and weight (Wt) and external odontoid diameters. Materials and Methods:: CT images of odontoid process of 100 consecutive patients were analyzed. Antero- posterior (AP) and transverse (TD), outer diameters of the odontoid process were measured from the base and at 1 mm interval upwards on axial CT images. Results:: The mean AP and mean TD were 11.52 mm and 9.85 mm, respectively. Fifty-five (55%) of the patients had at least one TD <9.0 mm. Five (5%) patients had at least one TD <7.4 mm. None of the patients had any diameter <5.5 mm. Body Ht correlated significantly with mean AP and m
Sign in with your free account to read, download EPUBs or listen.
Ebook · CT based evaluation of odontoid morphology in the Indian population. · Kulkarni, Arvind G, Shah, Siddharth M, Marwah, Ruchira A, Hanagandi, Prasad B, Talwar, Inder R · Internet Archive