This article is from Indian Journal of Critical Care Medicine : Peer-reviewed, Official Publication of Indian Society of Critical Care Medicine , volume 18 . Abstract Objective:: To Compare compliance versus dead space (Vd) targeted positive end-expiratory pressure (PEEP) as regard its effect on lung mechanics and oxygenation. Materials and Methods:: This study was carried out on 30 adult acute respiratory distress syndrome patients. The ventilator was initially set on volume controlled with tidal volume (Vt) 7 mL/kg predicted body weight (PBW), inspiratory plateau pressure (Ppl) 30 cm H2 O with a TV of 6 mL/kg PBW, a step-wise Vt reduction of 1 mL/kg PBW to as low as 4 mL/kg/PBW was allowed. Respiratory rate adjusted to maintain pH 7.30-7.45. FiO2 start at 100%. Best PEEP determined at 2 points, one by titrating PEEP until reaching the highest static compliance (Cst) (PEEP Cst) and the other one is at the lowest Vd/Vt (PEEP Vd/Vt). The following data measured before and 30 min after setting PEEP Cst and PEEP Vd/Vt. Cst, PaCO2 - PetCO2, Vd/Vt, PaO2 /FiO2, Ppl, heart rate, mean arterial pressure and oxygen saturation. Results:: optimum PEEP determined by Vd/Vt was significantly (P <